The Payment Card Industry (PCI) Data Security Standard is a joint creation of Visa, Mastercard, Discover and American Express. In response to the growing severity of credit card theft, the PCI Standard was created with the goal of protecting cardholder data wherever it may reside. The PCI has developed industry wide standards for card data security to be followed by both merchants and providers alike.

If you sell online and accept credit cards, then you MUST be PCI compliant. The deadline to become compliant has passed and it’s not something you can claim innocence toward. Click Here To Sign Up!

Need A Project Quote?
Request Custom Quote
BBB Accredited Business

Click to verify BBB accreditation and to see a BBB report.

 
Network Infrastructure

The Network Operations Center (NOC) is served by two separate high-speed OC-48-capable fiber optic connections and utilizes multiple Tier-1 Internet backbone providers. The facility is fitted with waterless fire-suppression systems, UPS and back-up generators, and environmental controls to ensure high-quality, uninterrupted service. The NOC is continuously monitored 24 hours a day, seven days a week. We've taken several crucial measures to make our world-class network infrastructure reliable and secure:

What Is A Data Center?
A data center is a web host's server and related equipment storage facility essential for hosting operations.

What Are The Criteria For A Great Data Center?
Redundant Internet Connectivity
Redundant Power Supply
Physical Security Properly Constructed Environment Host 99 data center meets and exceeds the criteria needed to be a success.

Redundant Internet Connectivity
Our customers access our data center and their accounts through premium gigabit Ethernet connections. The connection is multihomed, which is a technique that provides access to our network through multiple internet providers via numerous internet connections. The use of multiple internet connections ensures ultimate redundancy because if one network is unavailable, there are multiple other networks that provide connections.

Specific internet connectivity details include: Multihomed network connectivity via internet providers 1Gbps to Level(3), Savvis OC-48, & Global Crossing / XO (Shared 1Gbps)

Redundant Power Supply Power supply protection implementations by Host 99 data center make power outage concerns obsolete. The data center offers a number of redundant resources, including an Uninterruptible Power Supply which immediately provides power from other sources if main utility power becomes unavailable.

Host 99 data center is also equipped with Diesel backup generators that automatically turn on during the occurrence of a widespread power outage. The generator's 2000 gallon tank offers plenty of backup power capacity during long-term power outages

Specific power resources, including redundant power supply details, can be found below:
20A 120VAC UPS circuit
Dual-redundant 48 DC power feed
300kVA UPS uninterrupted power
480V 3-Phase building power
1200 AMP -48 DC Power Plant
750kVA Cummings Diesel Generator with 2,000 gallon tank
Physical Security
Security is another primary objective of our web host facility. Just as unauthorized access to our customers' data via our network is unacceptable, the same mindset is used regarding non-permitted entry to our servers via the data center. The following measures are applied at the Host 99's data center to ensure that security objectives are not just met, but exceeded.

Properly Constructed Environment
Temperature and humidity controls are vital in any data center to ensure the utmost reliability of our servers and related equipment. Through various measures, including the utilization of 15 air condition units, the A2 Hosting data center's environment is closely regulated. Each air conditioning unit is set at 68F and humidity levels are set to optimal levels between 30-40%. The use of static-free flooring, necessary for the elimination of data loss threats caused by static bursts, also contributes to the carefully designed data center's architecture.